Operation of an LHP with Multiple Heat Sources 2001-01-2191

Loop Heat Pipes (LHP) are widely used in space applications: deployable radiators, instrument cooling and precise temperature control. These applications are utilizing classical LHP designs with single evaporator and single condenser. Traditionally, the LHP is considered as an ideal solution for heat sources with concentrated power. The rule of thumb for a thermal control system based on the LHP is one heat source – one evaporator. It has been demonstrated several times that LHPs with dual evaporators are feasible, however, the volume of the compensation chamber grows dramatically with the number of evaporators. Therefore, LHPs with more than three evaporators are not practical. These restrictions restrict the area of LHP applications.
The LHP evaporator generates vapor, which travels through the vapor line toward the condenser. In principle, this vapor could be used to absorb some additional power from heat sources other than the heat source feeding the evaporator. But single-phase heat exchange between these secondary heat sources and the vapor is not very effective. However, if the vapor would be condensed prior to entering the secondary heat source, this condensed vapor with a quality close to zero would absorb significant amounts of heat from the secondary source. Ineffective single-phase heat exchange would be substituted by highly effective two-phase heat exchange. The chain of the secondary condensers and heat sources can be as long as the capillary pressure of the primary wick will permit. Its capillary pressure must support the additional hydraulic losses in the secondary condensers and heat sources. The evaporator of the driving pump must be connected to the heat source with the highest power. A system of this type was successfully tested, demonstrating reliable operation over a wide range of powers and temperatures. The paper is describes the test article and discusses the test results.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.
We also recommend:
TECHNICAL PAPER

Thermal Control with Low Power, Miniature Loop Heat Pipes

1999-01-2008

View Details

TECHNICAL PAPER

Thermal Control of Mars Lander and Rover Batteries and Electronics Using Loop Heat Pipe and Phase Change Material Thermal Storage Technologies

2000-01-2403

View Details

TECHNICAL PAPER

Advanced Loop Heat Pipe Evaporator with Ceramic Nanostructured Composite of Alumina, Alumina-Silica Oxide as a Wick Structure

2007-01-3192

View Details

X