Recommended Flame Ionization Detector Procedure for Automotive Exhaust Hydrocarbons 700468
This investigation indicates that a flame ionization (FID) analyzer can provide adequate response speed and accurate hydrocarbon analyses of automotive exhaust if a slight modification of commercial instruments, as well as adherence to specific operating conditions, is made.
Under these conditions the FID analyzer follows transients such as the California cycle at least as well as the standard NDIR hydrocarbon analyzer. The nearly uniform response of the FID to all hydrocarbons is much superior to the NDIR instrument. The greater sensitivity of FID analysis at low hydrocarbon concentrations is also well known.
Citation: Teague, D., Lesniak, E., and Loeser, E., "Recommended Flame Ionization Detector Procedure for Automotive Exhaust Hydrocarbons," SAE Technical Paper 700468, 1970, https://doi.org/10.4271/700468. Download Citation
Author(s):
D. Maxwell Teague, E. J. Lesniak, E. H. Loeser
Affiliated:
Chemical Research, Chrysler Corp.
Pages: 11
Event:
Mid-Year Meeting
ISSN:
0148-7191
e-ISSN:
2688-3627
Related Topics:
Hydrocarbons
SAE MOBILUS
Subscribers can view annotate, and download all of SAE's content.
Learn More »