1996-07-01

International Space Station THC/IMV Development Test and Analytical Model Correlation 961401

The International Space Station (ISS) Temperature and Humidity Control (THC) system has been reconfigured from the Space Station Freedom (SSF) configuration to meet new interface requirements and to implement a new “parasitic” air cooling scheme. This scheme provides Lab THC cooled air to Node 1, and more critically integrates Node 1 ports at different stages of space station assembly.
A joint development test of the complex U.S. Lab and Node 1 integrated THC/IMV ducting system was conducted in the summer of 1995 at the McDonnell Douglas test facility in Huntington Beach, California. The purpose of the test was to show overall capability of the ducting system to meet basic requirements, and to provide detailed flow and pressure drop performance data for individual duct segments.
This paper provides correlations of the test data with analytical data obtained from a computerized model of the THC/IMV ducting system. The applications of the correlated and adjusted math model include analyses for ground testing support, flight qualification, and flight support.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.
We also recommend:
TECHNICAL PAPER

Space Station THC/IMV Development Test/Analysis Correlations and Flight Predictions

972565

View Details

STANDARD

Accelerated Exposure of Automotive Exterior Materials Using a Fluorescent UV and Condensation Apparatus

J2020_202210

View Details

TECHNICAL PAPER

Understanding Water Vapor Gradients Conducive to Condensation in an Automotive Lamp

2005-01-1448

View Details

X