Test Method for Aerospace Firewall Sealant Flame Penetration
AS5127/2C
This SAE Aerospace Standard (AS) describes the test methods to determine the flammability performance and capability to control the passage of, and effects from, fire on aircraft firewall sealing compounds. The methods are based requirements of FAR Part 25 Sections 25.865, 25.867, 25.1191, and 25.1193 and may be used to demonstrate compliance with the requirements established by FAA AC 20-135. This standard shall be used in conjunction with applicable material specifications.
Rationale:
This is a Five-Year Review and update. Align specification material testing with new guidelines of FAA AC 20-135. Removed Class C requirement and testing associated with propane and bunsen burner testing of selaant. Provide for recommended sealant manufacturers minimum alternative sealant thicknesses. Specify instrumentation accuracy of the calorimeter (5.4) for heat flux density measuring device(s). Provide acceptable self-extinguishing time (7.2.3) for residual fuel burn off after withdrawal of ignition flame.
Related Topics:
Fire detection
Adhesives and sealants
Engine mounts
Aluminum alloys
Test procedures
Humidity
Also known as: SAE AS 5127/2
SAE MOBILUS
Subscribers can view annotate, and download all of SAE's content.
Learn More »